  Datasheet File OCR Text:
  linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference 100.8 w shut down and latch off o/p voltage , re-power on t o recover 2.1 200 max. min. 11 power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch rohs compliant lcvh-100  480 nrom. 48 dimension (l*w*h): 208.4 * 72 * 38.55 mm high operating ambient temp: -30 ~+70 (refer to output dreating curve) size 10 to +90%, non-cond. short circuit protection dc output voltage (v) model no. part no. protection: ovp / otp / scp / ocp ac input 90~305vac lcvh-100  480 plcvh1100  480 model name over v, protection pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac 120%~160% rated output power ; hiccup mode <0.45ma/264vac ac current operating temp.*(4) temp. coefficient safety relative humidity features output current(a) *(5) 90-305vac, 127-431vdc, normal 100-277vac safety: ul / tuv / cb emc: ce / fcc 2000ms,500ms at full load 115vac/230vac 1 power factor:>0.98@115vac;>0.95@230vac;@full load comply with indoor/outdoor waterproof (ip 67) ul 60950-1 / tuv en61347-2-13 / cb *(9) short circuit protection will restart automatically after the fault condition is removed over current protection 0.03% / (0-50 , typ) over temp. protection storage temperature -30 to +70 (refer to output dreating curve) -40 to +80 (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convecti on cooling. ce en55015 / fcc part15 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac isolation resistance dimensions(l*w*h) 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh emi withstand voltage 91% leakage current dimension (l*w*h): 8.2 * 2.83 * 1.52 inch active power factor efficiency(typ @full load) setup,rise time(typ.) inrush current (typ) o/p noise (p-p, mv) *(3) preset accuracy (%) *(8) module : lcvh-100  480 1.7a/115vac 0.65a/230vac line regulation (%) *(7) hold up time dc output power input voltage range load regulation (%) *(6) 25ms at full load 115vac/230vac range:47-63hz, normal 50-60hz input frequency www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch size model no. part no. lcvh-100  480 plcvh1100  480 model name reference unit :mm inch derate dimensions www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of LCVH-100X480

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X